Ontario Building Code - Section 258
Sarah's Expert Insight
OBC Compliance Specialist
"The Ontario Building Code (OBC) contains specific amendments tailored for Ontario's unique environmental and safety needs."
3.2.2.55E. 2024 Building Code Compendium 72 Division B – Part 3 3.2.2.55E. Group C, Retirement Home, up to 3 Storeys, Sprinklered, Combustible Construction (1) A retirement home is permitted to conform to Sentence (2) provided (a) except as permitted by Sentences 3.2.2.7.(1) and 3.2.2.18.(2), the building is sprinklered throughout, (b) it is not more than 3 storeys in building height, and (c) it has a building area not more than (i) 4 800 m 2 if 1 storey in building height, (ii) 2 400 m 2 if 2 storeys in building height, or (iii) 1 600 m 2 if 3 storeys in building height. (2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible construction used singly or in combination, and (a) floor assemblies shall be fire separations with a fire-resistance rating not less than 45 min, (b) mezzanines shall have, if of combustible construction, a fire-resistance rating not less than 45 min, and (c) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. 3.2.2.56. Group D, Any Height, Any Area, Sprinklered (1) Except as permitted by Articles 3.2.2.57. to 3.2.2.65. and 3.2.2.93., a building classified as Group D shall conform to Sentence (2). (2) Except as permitted by Article 3.2.2.16., the building referred to in Sentence (1) shall be of noncombustible construction, and (a) except as permitted by Sentences 3.2.2.7.(1) and 3.2.2.18.(2), the building shall be sprinklered throughout, (b) floor assemblies shall be fire separations with a fire-resistance rating not less than 2 h, (c) mezzanines shall have a fire-resistance rating not less 1 h, and (d) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. 3.2.2.57. Group D, up to 12 Storeys, Sprinklered, Encapsulated Mass Timber Construction (1) A building classified as Group D is permitted to conform to Sentence (2), provided (a) it is sprinklered throughout, (b) it is not more than 12 storeys in building height, (c) it has a height of not more than 42 m measured between the floor of the first storey and the uppermost floor level that does not serve as a rooftop enclosure for elevator machinery, a stairway or a service room used only for service to the building, and (d) it has a building area not more than 7 200 m 2 . (2) Except as provided in Article 3.2.2.16., the building referred to in Sentence (1) is permitted to be of encapsulated mass timber construction or noncombustible construction used singly or in combination, and (a) floor assemblies shall be fire separations with a fire-resistance rating not less than 2 h, (b) mezzanines shall have a fire-resistance rating not less than 1 h, and (c) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. (3) Group A, Division 2 major occupancies, Group E major occupancies, Group F, Division 2 and 3 major occupancies and storage garages located in a building or part thereof within the scope of this Article are permitted to be constructed in accordance with this Article, provided (a) the Group A, Division 2 major occupancy is located below the fourth storey, (b) the Group E major occupancy and Group F, Division 2 or 3 major occupancy are located below the third storey, and (c) the storage garage is located below the fifth storey. (See also Article 4.4.2.1.) (See Note A-3.2.2.48.(4), 3.2.2.57.(3), and 3.2.2.93.(5) to (7)) r 1 r 1 e 1
Disclaimer: This content is generated from the Ontario Building Code for educational purposes. Always consult with a licensed professional engineer or your local building department before starting any construction project in London, Ontario.