"Navigating the fire-resistance requirements for Group F Division 2 occupancies is critical for industrial developers in London and Muskoka to avoid costly mid-construction retrofits. By partnering with empcontracting.ca Inc. your construction contractor in London, Ontario, you ensure that every mezzanine and floor assembly meets the precise 45-minute to 2-hour ratings mandated by the 2024 Building Code."

Understanding the 2024 Ontario Building Code (OBC) requirements for Group F, Division 2 (medium-hazard industrial) buildings is essential for ensuring safety and legal compliance. Whether you are developing a large-scale warehouse or a smaller industrial workshop, empcontracting.ca Inc. your construction contractor in London, Ontario, provides the expertise needed to navigate these complex fire-safety regulations.

3.2.2.77: Sprinklered Industrial Buildings up to 4 Storeys

Article 3.2.2.77 outlines provisions for buildings with increased areas, provided they are equipped with a sprinkler system. These structures must be of noncombustible construction to mitigate risks associated with medium-hazard industrial operations.

Noncombustible Construction Requirements

  • Building Area: Maximum areas range from 18,000 m² for 1-storey structures down to 4,500 m² for 4-storey structures.
  • Fire Separations: Floor assemblies must have a fire-resistance rating of no less than 1 hour.
  • Support Structures: Loadbearing walls, columns, and arches must maintain a fire-resistance rating equal to the supported assembly.

3.2.2.78: Small to Mid-Sized Industrial Buildings (Up to 3 Storeys)

For projects with a smaller footprint, Article 3.2.2.78 allows for both combustible and noncombustible construction. This provides flexibility for developers in areas like Muskoka and London where timber-based construction may be preferred for certain industrial applications.

Fire-Resistance Ratings for Combustible Builds

When utilizing combustible construction, the OBC mandates specific fire-resistance ratings to ensure occupant safety:

  • Floor and Roof Assemblies: Generally require a minimum fire-resistance rating of 45 minutes.
  • Mezzanines: Must be rated at 45 minutes if constructed from combustible materials.
  • Roof Waiver: For 1-storey buildings, the roof assembly rating may be waived if fire-retardant-treated wood is used in accordance with Article 3.1.14.1.