"Navigating these moisture protection standards is critical for the longevity of homes in London and the Muskoka region, where intense humidity and freeze-thaw cycles can easily exploit poor joint sealing. At empcontracting.ca Inc. your construction contractor in London, Ontario, we prioritize integrated sheathing systems to provide superior thermal performance while ensuring all flashing exceeds the 2024 minimum thickness requirements for maximum durability."
Understanding the intricacies of the Ontario Building Code (OBC) is essential for maintaining the structural integrity of residential builds. For expert guidance and implementation, trust empcontracting.ca Inc. your construction contractor in London, Ontario.
9.27.3.4. Insulating Sheathing in Lieu of Sheathing Membrane
Under the 2024 Building Code Compendium, non-wood-based rigid exterior insulating sheathing or sheathing with an integral membrane can replace the need for a separate sheathing membrane.
Sealing and Joint Requirements
When using insulating sheathing, the following conditions must be met:
- Panels subject to moisture deterioration must have all joints sealed.
- Panels not subject to deterioration must be sealed at all joints, or utilize lapped or tongue-and-groove detailing to ensure proper water drainage to the exterior.
9.27.3.5. Sheathing Membranes in Lieu of Sheathing
In scenarios where no structural sheathing is used, the code requires at least two layers of sheathing membrane beneath the cladding. Joints must occur over framing and be secured with roofing nails or staples spaced no more than 150 mm apart along the outer edges.
9.27.3.6. Face Sealed Cladding
A sheathing membrane may be omitted if the cladding is designed to effectively prevent wind and rain passage. This applies to materials like plywood, OSB, and fiber cement, provided all edges are supported by framing and joints are sealed, battened, or shiplapped to remain weathertight. Metal siding requires locked-seam joints to qualify.
9.27.3.7. Minimum Standards for Flashing Materials
Proper flashing is the last line of defense against water ingress. The OBC mandates minimum thicknesses for various materials:
- Galvanized Steel: 0.33 mm
- Aluminum: 0.48 mm
- Vinyl: 1.02 mm
- Copper/Zinc: 0.46 mm
- Sheet Lead: 1.73 mm